CONTACT ELEMENT, 1 N/C, FRONT MOUNT, 6. CONTACT, SCREW CONNECTION. M22-K01
Article No.:
216378
Part No.:
M22-K01
Brand:
Contact element, Screw terminals, Front fixing, 1 NC, 24 V 3 A, 220 V 230 V 240 V 6 A
Regular Price
AED 5.65
Special Price
AED 4.52
Availability:
Forward delivery 5-7 weeks
No Related Posts
| Part No. | M22-K01 |
|---|---|
| Minimum Count | 1 |
| UOM | EA |
| Minimum Order Quantity | 1 |
| Weight (KG) | 0.01 |
|---|---|
| Dimension Width (mm) | 32.00 |
| Dimension Height (mm) | 10.00 |
| Dimension Depth (mm) | 38.00 |
Description
Contact element, Standard/Approval: UL/CSA, IEC, Construction size: NZM1/2/3/4, Connection technique: Screw terminals, Fixing: Front fixing, Contacts N/C = Normally closed: 1 NC, Contacts Notes: = safety function, by positive opening to IEC/EN 60947-5-1, Actuator travel and actuation force as per DIN EN 60947-5-1, K.5.4.1: mm 4.8, Maximum travel: mm 5.7, Minimum force for positive opening: N 15, Degree of Protection: IP20, Connection to SmartWire-DT: no, Connection type: Single contact, Description of HIA trip-indicating auxiliary contact: General trip indication '+', when tripped by shunt release, overload release, short-circuit release or by the residual-current release due to residual-current., Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM4 circuit-breaker: up to two standard auxiliary contacts can be clipped into the circuit-breaker., Any combinations of the auxiliary contact types are possible., Not in combination with switch-disconnector PN…, Marking on switch: HIA, Labeling in FI-Block: HIAFI., If the trip-indicating auxiliary switch in the fault current block is used, the NC contacts operates as a N/O contact and the NC contact operates as an N/O contact., Description standard auxiliary contact HIN: Switching with the main contacts Used for indicating and interlocking tasks., Can be used with NZM1 circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM2 size circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary contacts can be clipped into the circuit-breaker., Any combinations of the auxiliary contact types are possible., Marking on switch: HIN., On combination with remote operator NZM-XR... the right mounting location of standard auxiliary contact HIN can be fitted only with individual contacts., For use with: NZM1(-4), 2(-4), 3(-4), 4(-4), PN1(-4), 2(-4), 3(-4), N(S)1(-4), 2(-4), 3(-4), 4(-4), Standards: IEC 60947-5-1
Resources / Data Sheets
Related Products
-
Regular Price AED 1,988.10 Special Price AED 1,590.48
Part No.: LZMN3-AE630-IMCCB 3P 630A 50KA FRAME3 LI EL. LZMN3-AE630-IUOM: EAAvailability: In stockAED 1,405.36
Regular Price AED 203.32 Special Price AED 162.66
Part No.: XBTPR1603FMEMCB DISTRIBUTION BOARD 16MOD 3ROW-FLUSH TYPE. XBTPR1603FUOM: EAAvailability: In stockRegular Price AED 14,272.67 Special Price AED 11,464.86
Regular Price AED 2,043.28 Special Price AED 1,634.63
Part No.: IZMC2-CAS323-2000Electronic Trip Unit, 2000A, for IZMC2 Air Circuit BreakerUOM: EAAvailability: In stockRegular Price AED 390.99 Special Price AED 195.49
Part No.: XBTPR1604SMEMCB DISTRIBUTION BOARD 16MOD 4ROW-SURFACE TYPE. XBTPR1604SUOM: EAAvailability: In stockRegular Price AED 38.11 Special Price AED 19.05
Part No.: DILM150-XHI40AUXILIARY CONTACT MODULE, 4N/O. DILM150-XHI40UOM: EAAvailability: In stockRegular Price AED 7,648.51 Special Price AED 5,627.99
Regular Price AED 136.09 Special Price AED 68.04
Part No.: DILM32-01(240V50HZ)Power Contactor, 32A, 1NC, 240V AC 50Hz CoilUOM: EAAvailability: In stockRegular Price AED 183.57 Special Price AED 91.78
Regular Price AED 40.37 Special Price AED 32.30
Regular Price AED 86.17 Special Price AED 43.09
Part No.: DILM15-10(230V50HZ,240V60HZ)CONTACTOR, 3P+1N/O, 7.5KW/400V/AC3. DILM15-10(230V50HZ,240V60HZ)UOM: EAAvailability: In stock