Circuit-breaker, 3p, 320A
Article No.:
109681
Part No.:
NZMN3-S320
Brand:
Circuit-breaker, 3p, 320A
Regular Price
AED 1,741.78
Special Price
AED 1,393.42
Availability:
Forward delivery 5-7 weeks
No Related Posts
| Part No. | NZMN3-S320 |
|---|---|
| UOM | EA |
| Weight (KG) | 5.80 |
|---|---|
| Dimension Width (mm) | 140.00 |
| Dimension Height (mm) | 275.00 |
| Dimension Depth (mm) | 166.00 |
Description
Variable frequency drive, Part group reference (e.g. DIL): DG1, Rated operatiol voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-15%) - 500 (+10%) V, Rated operatiol current At 150% overload: Ie = 61 A, Note: Rated operatiol current for a switching frequency of 1 - 10 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload, Rated operatiol current At 110% overload: Ie = 72 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal interlly and exterlly ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 30 kW, 110 % Overload: P = 37 kW, 150 % Overload: IM = 55.2 A, 110 % Overload: IM = 68 A, Assigned motor rating Note: at 500 V, 50 Hz, Assigned motor rating 150 % Overload: P = 37 kW, 110 % Overload: P = 45 kW, 150 % Overload: IM = 54 A, 110 % Overload: IM = 65 A, Assigned motor rating Note: at 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 40 HP, 110 % Overload: P = 50 HP, Assigned motor rating 150 % Overload: IM = 52 A, 110 % Overload: IM = 65 A, Degree of Protection: IP21/NEMA1, Interface/field bus (built-in): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Fieldbus connection (optiol): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Fitted with: Radio interference suppression filter, Additiol PCB protection, Multi-line graphic display, Brake chopper, DC link choke, Frame size: FS4, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-4738
Resources / Data Sheets
Related Products
-
AED 100.00
Part No.: 378355*S400-PE APG 3P 400A FC MCCB Icu 85kA ElectronicUOM: EAAvailability:Forward delivery 5-7 weeksAED 16.66
Part No.: EZ9F56120Easy9 miniature circuit breaker- 1P - 20 A - C curve - 6000 A - 230 VUOM: EAAvailability: In stockAED 11.29
AED 27.37
AED 109.05
AED 11.55
AED 2,453.58
AED 2.37
AED 0.27
AED 42.54
Regular Price AED 297.59 Special Price AED 238.07
Part No.: LZMB1-A25-IEaton Moeller series Power Defense - Molded Case Circuit BreakerUOM: EAAvailability:Forward delivery 5-7 weeksAED 100.00
Part No.: 552977S1250-SE AP 4P 1250A FC MCCB Icu 50kA ElectronicUOM: EAAvailability:Forward delivery 5-7 weeks